Dell switch cli commands

5. This updates the selected parameters in the running-config file. exit; show ip interface vlan 1. End with CNTL/Z. “date” command will be a read-only if a switch is configured with a Time server – NTP. These commands provides comprehensive output & can be used for general health check too. CLI commands can be scripted and then the script can be run on multiple service processor (SP) instances. old, then when you log back into the switch, go into privileged mode, then rename those files back to their original config. The goal of network_cli is to make playbooks look, feel and operate on network devices, the same way Ansible works on Linux hosts. ) Hit “Y” to setup the switch. Step 1: Connect to Dell Switch with Putty. Mar 20, 2013 · I save my session and called it “Dell Switch” so that I can easily connect again to the switch. To install the diagnostic tool, use the CLI command: Onie-nos-install <location>/<Diag file name> Example: Data center solutions from Dell and Cisco By combining Dell’s servers and storage (PowerEdge, EqualLogic, Dell/EMC and PowerVault) with Cisco’s Nexus and Catalyst Ethernet switches, you can achieve a unified fabric data center solution. c) Set the data format to 8 data bits, 1 stop bit, and no parity. If I’m not using brand new switch, I normally like to reset it back to factory defaults before doing anything. switch# logging monitor information. No commands work in the CLI, it just gives you this prompt: > If you type say enable, or login, it gives: >login Unknown parameter May be one from the following list: debug help So no commands seem to work. config Commands stored in the buffer are maintained on a First In First Out (FIFO) basis. Download the latest upgrade candidate from the support website. Passwords are used to restrict physical access to switch. " See the Command Line Reference on the documentation CD for a list of all  This document provides the steps for configuring and troubleshooting the Dell EMC PowerEdge MX networking switches in SmartFabric mode. You can put your port or LAG in the following 3 (main) modes: Shell Script Commands echo -- Displays messages or turns command echoing on or off for/endfor -- Executes commands for each item in a set of items goto -- Makes batch file execution jump to another location if/endif -- Executes commands in specified conditions The examples here are shown with output in plain text. In a script, by using this command with a time limit specified, you can run gpupdate and continue with commands that do not depend upon the completion of gpupdate. 168. FTOS running on the E-Series, S-Series and Z-Series switch/router platforms Dell EMC Unity™ Family Version 5. ) Hit OPEN in the Putty Session window. The most common release is 2. In SmartFabric mode, the VLT domain ID is 255. This article discusses the limited amount of commands available through the command line on Dell Networking PowerConnect 2800 model switches. The vagrant command in turn has many subcommands, such as vagrant up, vagrant destroy, etc. 5. 255. What are the X-Switch default credentials? The default user is admin; The default user password is admin . Sep 30, 2015 · show wwn switch show switch summary show version show cdp neighbors show boot show system internal flash show snmp host show ntp peers show ssh server show telnet server. 2. PowerOne component updates, including Dell EMC PowerEdge MX7000, Dell EMC PowerMax, networking, and PowerOne Controller updates . However, CLI mode does not have all of the features and commands that BASH offers. Let’s show a simple example using the cli_command, on an Arista vEOS device. The following table summarizes the equivalent CLI commands for items in the Switch/Security/Passwords page. 1. The Command Line Interface (CLI) can be used to configure and manage the Switch via the serial port or Telnet interfaces. x derived from Force10 OS (FTOS). SSH to the switch & login. 6500 6500 alom Battery brocade cisco cli collection data Dell disk dsa emc fiber hp hp9000 hpe hpux In this lab I use a Dell Force10 S25P switch [FTOS 8. Switch over the specified replication consistency group. (Netgear Switch) (Config)#access-list 102 permit ip any; Apply ACLs 101 and 102 to port 0/44; the sequence of 101 is 1 and of 102 is 2. 7. Basic CLI Overview The PowerConnect 28xx series supports a basic console CLI interface and a single telnet session. 3(0. Mar 30, 2020 · To configure each of these banners and set them up on your switch, follow these commands: SW1#enable SW1#configure terminal Enter configuration commands, one per line. This guide contains the information needed for installing, configuring, and maintaining these devices through the web-based network administrator. old and vlan. 10 255. The CLI is an interface, based on text. A command-line interface (CLI) processes commands to a computer program in the form of lines of text. Run the switchshow command. You will need to type in the IP of the switch as the client. 1 255. ESX 3. Page 63 Keyboard Shortcuts The CLI has a range of keyboard shortcuts to assist in editing the CLI commands. their controller). VLT commands show vlt domain_id. This command is used to validate the VLT configuration status. Diagnostic log-gathering commands for an M1000e enclosure. Operating systems implement a command-line interface in a shell for interactive Aug 31, 2015 · If you are starting to deploy Windows 10 (or are currently deploying Windows 8/8. S5248F-Leaf1A# show vlt 255 Dec 17, 2018 · This tutorial will walk you through step by step on how to enable secure SNMPv3 on a Dell X1052 switch, although this will work on any of the X series switches. 0) or version 6. Now, you know why I should tell you consider the budget. The first one sets the timeout for the specific line and the second one stops annoying pop-up messages from disrupting whatever you are trying to type. There are three methods to retrieve the serial number (S/N) from an EX Series switch (EX3200 and EX4200). You will notice the switch will start to boot. Learn these ESXi troubleshooting commands now so you're ready when a problem strikes. Thanks for the article. When you save the configuration, these commands are saved across switch reboots. Principal switch will update the time in all the non principal switches. From the command line, you can navigate through files and folders on your computer, just as you would with Windows Explorer on Windows or Finder on Mac OS. 7: Switch Booting Commands 7. You access the switch CLI from a console terminal connected to an EIA/TIA-232 port or through a The following are the CLI commands used to show ip interface in the proxy ARP feature. Up to 256 VSANs can be configured in a switch. This topic set is for installers, system and network administrators, developers, service personnel, and any user qualified to install, manage, or service InfiniBand networking devices. With just one tool to download and configure, you can control multiple AWS services from the command line and automate them through scripts. racadm dumplogs – Hidden command. Dell's version seems to be stripped down to some extent, and doesn't state many of the commands the same way Cisco does. Using the CLI commands described in the section beginning with TFTP: Copying a configuration file to a remote host (CLI), you can copy switch configurations to and from a switch, or copy a software image to configure or replace an ACL in the switch configuration. 0. How to set a management IP on a Dell powerconnect 5524 Dell powerconnect 5424 cli reference guide. A system needs to be configured for UEFI (without Compatibility Support Module being enabled) in order to take advantage of Secure Boot (and other Windows 10 security features like Device… Jun 08, 2016 · How to get a Brocade switch configured for Dell EMC SRS (ESRS) How to find out the LUN id of a Windows disk; Useful EMC VMAX CLI commands; How to list the naa-numbers of LUNs and VMware VMFSs on a Dell EMC Unity system; Setting the queue depth or Execution throttle parameters - Clariion / VNX Chapter 1 Using Command Line Interface . I cannot guarantee this guide will work with Windows Vista or Windows XP. To change or add a user and its password: Use the Aug 10, 2017 · I always thought, that the command line of the Comware OS based 1910/1920 switches are limited because they are “cheap”. Jul 05, 2016 · Here are some commands that may come in handy for Dell systems. For more information about the ATM module CLI, refer to the "ATM Command-Line Interface" chapter. 5 create sflow counter_poller ports all analyzer_server_id 1 interval 30 create sflow flow_sampler ports all analyzer_server_id 1 rate 128 Dec 22, 2017 · The default logging level for Console and VTY lines is Debugging. Thank you for these useful tips. Physical Location - Locate the serial number on the EX Series switch chassis. Now here comes to cool part, you can use standard Linux functions on your CLI commands with pipe: Switch#show ip route | nl | grep 14 14: S* 0. Enter the following commands. The following is an example of using the volume create command to create a volume and then using subcommand mode to specify a description for the volume and FC Switch (admin-config) #> FC Switch (admin-config) #> config save The config named default has been saved. When you SSH to the switch you only get a linux shell prompt rather than a command line interface. The switch is currently the Master. For the Dell M1000e there are two model-ranges for Ethernet switching: (note: Cisco also offers the Catalyst 3030, but this switch is for the old Generation 8 or Gen 9 blade system, not for the current M1000e enclosure) • USB auto-configuration rapidly deploys the switch without setting up complex TFTP configurations or sending technical staff to remote offices. In this case, Debugging logs will not be shown. To enable DHCP client and remove the static IP address (AH-Switch) #network protocol dhcp. Let’s hope this works. Datil. 1 To access the CLI to run the restart command, see Running Array Management Commands. 0, with over 98% of all installations currently using this version. Leverage Dell and Cisco together to simplify, unify and consolidate your data center environment. All systems were running Windows 7 Professional x64 and Windows 10 Pro x64. Dell. You can use the tool directly in a command shell, or indirectly through an interactive UI such as Angular Console. For example, Command Prompt commands let you copy data to a different folder, format an entire disk, back up your files, send messages to other computers, restart your own computer, and With commands that use the select subcommand, press the <Enter> key after each component selection. Jul 31, 2019 · This VMware ESXi command line cheat sheet can help you automate management tasks and troubleshoot your virtualization environment through the ESXi CLI if vCenter is unavailable. FastPath OS: Enable the HTTP server (AH-Switch) #ip http server This will allow you to access the switch via the web GUI to perform other settings and changes such as updating the firmware. Command Mode Overview. Correct, the console port is what you will need to connect your laptop up to the switch. These include your security credentials, the default output format, and the default AWS Region. Also for: Powerconnect 6224p, Powerconnect 6224f, Powerconnect 6248, Powerconnect 6248p. With a CLI, you aren’t waiting between commands and with a GUI interface, you are. FTOS software architecture Figure 2. The switch automatically detects whether the cable connected to an RJ-45 port is crossed or straight through. Oct 21, 2012 · Configure HP Procurve Switch via Command Line Interface Posted on October 21, 2012 by Tyrone After getting my eyes of a Cisco 2960 configured created by DEECD, I decided to replicate their config on our HP Procurve switches. Aug 31, 2015 · Compare CLI commands, get tips and tricks for configuring on specific platform, and view at-a-glance sample configurations in each section. Once you get to the CLI prompt, configure hostname and enable SSH: # hostname n4032f-prod The CLI offers these privilege levels to help protect the switch from unautho-rized access: 1. Brocade SAN Switch commands. . 5. Immediately after logon, an admin is always in the view mode. If you have much money, you can buy Cisco switches and ready to buy many licenses in order to get more functions. Sep 11, 2013 · This is a list of useful Brocade CLI commands that I keep at my desk for reference. A unit is selected as standby by the administrator, and a fail over action is manually initiated or occurs due to a Master unit failure. The following illustration shows the setup screen with the defaultsettings. Configuring Port Mirroring for Local Traffic Analysis, Configuring Port Mirroring for Remote Traffic Analysis, Filtering the Traffic Entering an Analyzer I thoughts that it might be a good idea to put a list of commands which are used to manage ESXi hosts. set the terminal emulator to 9600 baud rate, 8 data bits, No Parity, 1 Stop Bit, No Flow Control. 114. I’ve done this both via ssh and via the serial port. Dell PowerConnect M6220 Manual Online: Simple Switch Mode Supported Cli Commands. Jan 06, 2017 · About Router-Switch. The Crosh shell opens in a new browser tab. I've been playing around with using the Dell Command Update CLI to run directly from a package without installing the utility. ) Dec 14, 2019 · One of the most powerful command in IOS is Show. force10-mxl-blade Dell Networking Command Line Reference Guide for the MXL 10/40GbE Switch I/O Module 9. I tested these steps on a Dell OptiPlex 780 SFF (Small Form Factor), Dell OptiPlex 790 SFF, and Dell OptiPlex 3040 MT (Mini-Tower). The Role for one switch in the VLT pair is primary, and its peer switch (not shown) is assigned the secondary role. Hardware List: The following section presents the list of equipment used to create this HP Switch tutorial. For one, the command line is the only place you can run all Git commands — most of the GUIs implement only a partial subset of Git functionality for simplicity. See the Dell EMC PowerOne System Version 1. The credentials can be found in your UniFi controller’s settings. The command line interface is a text-based interface navigated by typing commands at prompts to configure and manage networking devices. Follow the below procedure to create zone from CLI1. Step 2: Configure the GSM7352S. 0 beğenilme . The following table describes the CLI To access the group to run CLI commands, use one of the following connections: Network connection . Reset switch to factory defaults. tsclockserver is the command used to associate a switch to a NTP time server. 2. How to set password on a Catalyst switch. Mar 13, 2008 · Dell PowerConnect 5448 Switch IP Change I'm trying to change this ip now but cant seem achieve this through the web interface, ive also tried using CLI but cant find where it is configured. 6200 Series Systems. This document is intended as a reference guide for the Dell Networking OS command line interface (CLI) commands, with detailed syntax statements, along with usage information and sample output. Unfortunately I could not figure out how to do this to the range like in the example below – it’s likely possible, but after the interface range command, trying to give the command default wanted another parameter, and I didn’t want to have to reset each config to default, so I just rant the above command for each interface, then did bulk range operations for applying the vlans. RACADM commands allow you to view managed system information, perform power operations on the managed system, perform firmware updates, configure settings and more. 16) on an N20xx or N30xx system Dell Networking OS Conversion Guide for the N20xx/N30xx Series Latest updates Dell Networking C9010, C1048P, and N20xx/N30xx Series Release Notes 1 About this Guide 3 Dell Command | Update CLI - BIOS updates only I'm trying to build BIOS updates into our Windows 10 task sequence. 1 görüntülenme. Uptime Command. Below is a series of screenshots and several commands on the Dell N1548 switch (For more information on how technical it can be, see the 2410 page Dell PDF If it is already installed, you will see a menu option for DELL-DIAG in the ONIE GRUB boot menu. Discover where 3rd party SFPs can be used without hesitation. Jun 01, 2017 · Some people strongly prefer the CLI (source: Imgur) As the cloud has grown in popularity, AWS has become the undisputed market leader, powering many of the internet giants and setting the pace for Mar 29, 2018 · Opening Crosh. 0 3 Listed below are the new features for FTOS version 6. Customers can also take advantage of a centralized CLI from Dell Technologies to configure, manage, and monitor SONiC-powered switches. 17, Temmuz, dell switch ssh enable disable; dell switch cli komutları A banner is a message presented to a user who is using the Cisco switch. Note the restrictions on the destination port (the port to which switch traffic will be sent, and into which you'll plug the interface on which you'll capture traffic) and the source ports (ports that are to be monitored). dell switch update upgrade commands. 4ghz connection because it was stronger. As I mentioned above I changed from CRLF to LF hoping IOS would like it better, but that failed. However, the Command Prompt is not MS-DOS and the commands are not MS-DOS commands If you're interested in why a command was removed or when it was first available, you can see every command from MS-DOS through Windows 8 or skip the details and see it all in our one The show running-config command shows the router, switch, or firewall's current configuration. b) Set the data rate to 9600 baud. The following commands apply to the D-Link xStack® DGS-3600 series switch: enable sflow create sflow analyzer_server 1 owner analyzer1 timeout infinite collectoraddress 10. Jul 03, 2016 · When it comes to networking Dell has two main series of switches. Here is an example of how to apply these commands: As you can see FTOS command line interface (cli) is very similar to CISCO. If you use a naming convention for QoS CLI such as 100M-5Mpri-15mbAF21 then this is a hugely useful feature for show and configuration commands. Connect the RS-232 cable to the switch console port on the front panel of the switch using an 8-pin RJ-45 male connector. I was calling Dell tonight to troubleshoot, and thought I’d give google another crack first. Jan 12, 2018 · I’m going to change it via a combination of the controller and the CLI. In Linux uptime command shows since how long your system is running and the number of users are currently logged in and also displays load average for 1,5 and 15 minutes intervals. Please note that this guide only applies to Dell systems. GeneralRead More Cisco Switch Commands Cheat Sheet (CLI) Cisco switches can be used as plug-and-play devices out of the box but they also offer an enormous amount of features. Dell PowerConnect 6248 Command Line Interface Guide; 2 Comments. Icinga 2 CLI Commands ¶ Icinga 2 comes with a number of CLI commands which support bash autocompletion. This is because there are multiple declarations for the same This section explains how to configure the settings that the AWS Command Line Interface (AWS CLI) uses to interact with AWS. Useful but VERY verbose logs; racadm racdump – Less verbose than dumplogs; racadm getsel – Grab the SEL (System Event Log) from the chassis; racadm getraclog – Similar to getting When you run a command, Unisphere CLI will run the command on the default system. 26 −−accept_license Login to MDM cli −−mdm_ip 192. On the other hand, even if you are a seasoned administrator Note. No Distributed Virtual Switch (DVS) nor Cisco Nexus 1000v for iSCSI traffic Not every environment will require all of the steps detailed in this Technical Report. VLANs are local to each switch’s database, and VLAN information is not passed between switches. Sep 04, 2016 · HP Switch CLI Commands. This module includes an argument that will cause the module to wait for a specific condition before returning or timing out if the condition is not met. 0 beğenilmeme. Now assume you have a server named “TRAINING” with two HBA hba1 and hba2 and a storage clarion with FE ports A0. the system is powered off. Operator 2. David Davis discusses the pros and cons Windows 7 and 8 supports a feature that allows you to switch accounts on the same computer without logging out the first one. The PowerConnect 5424 delivers significant price/performance benefits to customers. Then configure your terminal: a) Select the appropriate serial port to connect to the switch. Please be mindful that entering the support layer of an EqualLogic is not supported in a normal situation by EqualLogic as stated in the message you will recieve upon entering. fm PowerEdge VRTX 10Gb Switch Describes how SmartFabric Services is used to deploy a greenfield leaf-spine fabric. It is generally good practice to use unique host names because you know on which system you are logged in. d) Set Flow Control to none. 26 −−login −−username admin Change password cli −−set_password −−old_password admin −−new_password Password123! msiexec. For details on all of the specific options for each of these commands I recommend downloading the (612 page long) Dell EMC CLI Reference Guide . The TAB button is auto-completion for both commands and file/device paths. Dell: HP: IBM/Lenovo: Tags. 3. Global Configuration 4. switch# logging console information. From the Crosh prompt, you can run the help command to view a list of basic commands or run the help_advanced command for a list of “more advanced commands, mainly used for debugging. Switchover is a planned failover. You can configure three main types of banners on your Cisco switch, as shown here: Message of the Day (MOTD): This type of logon message has […] There are 5 commands that every Cisco network administrator should know. Therefore it has no knowledge about half-open or completed connections that is has routed (or even switched). From a computer, use telnet or SSH to connect to the group (or management) IP address or — if you are running array management commands on a specific array—connect to an IP address assigned to a network interface on the array. Delete one or more files. 24 Apr 2019 I picked up a Dell Powerconnect 6224 switch the other day as my older Netgear switch 1- Went back into the console and entered the following command. Jun 16, 2014 · Please realize that switch behavior (especially for trunk mode in this context) has changed over time with more recent switches/firmware. Dec 30, 2009 · Still, my first experience with the 2824 had me stuck at the same place… with a limited CLI, and non-senible WebGUI, thinking that the switch must be defective. - Configure the backups on the client To list the group policies on an Avamar: mccli group show --recursive=true: 0,23000,CLI command completed successfully. For instance, you need help with commands on a switch or having trouble finding the right command for your configuration. If you want to defend the switch itself against DoS attacks you should move the management to a VLAN that normal users can't connect on. Sep 16, 2014 · Useful Brocade SAN Switch CLI commands. 2(25)SEE3] to demonstrate 802. They are divided up into categories for Zoning, Show, Port, Time/Date, License, Banner, Password, SNMP, User Config, Firmware, and Miscellaneous. com Dell Command | Update is installed as a standalone application on a business client supported platform to provide a Windows update experience for systems software released by Dell. com is the World's Leading Network Hardware Supplier, founded in 2002. This step will return the Gateway and IP Address of the switch confirming your commands earlier stuck. IPMI Alerts. During setup, the program registers itself to launch on boot through a Windows Schedule Task in order to automatically start-up. 3. Alternatively, you can use this command with no time limit specified to let gpupdate finish running before other commands that depend on it are run. All N-Series switches include Dell Networking OS 6 designed for easier deployment, greater interoperability and a lower learning curve for network administrators. Note: Use the same method to launch standalone Unity applications. 0 Release Notes for further details. Other Posts in This Series. This guide may help you to rough idea and basic commands of IPTables where we are going to describe practical iptables rules which you may refer and customized as per your need. hostname f10-s60 † Section 7. Nov 16, 2013 · IPTables is a front-end tool to talk to the kernel and decides the packets to filter. 254. All supported lines need be secure for User Exec mode. switches that are installed in the Dell PowerEdge VRTX chassis. The SVI is a virtual interface, not a physical port on the » Command-Line Interface. When working with VMware ESXi and vSphere, there is a time when you have to go into the CLI and fix problems, look for details which you don't get through the UI or those details would be many clicks away. 10. In this series of blogs we will go through the configuration of Force10 switch series and use Dell S4048-ON top of the rack switch as an… May 18, 2014 · Utilize vSphere CLI Commands to Troubleshoot ESXi Network Configurations To troubleshoot networking configurations from the ESXi command line, ESXCLI is the tool to use. Some commands have options and parameters, while others do not. enable password [level level] {0 | 7} password Use this command to control access to the Privileged Exec level from the Normal Exec level. 4. This command can similarly be used for patching or uninstalling software as well. In addition to offering a secure, high-performance networking platform and delivering advanced network management features, the PowerConnect 5424 is the world's first switch which self-optimizes for iSCSI storage traffic. iDRAC. This manual provides a reference for all of the commands contained in the Solved: Can someone show me the commands to find a mac-address on a switch and if I know the port I am looking to find it on, also how i find the IP address on that port As you know, UniFi Switches are controlled and configured through the UniFi Controller. Thanks much for your pain in sorting this out for the rest of us. What can you do with the cli_command? The cli_command allows you to run arbitrary commands on network devices. These modes execute different switch commands. Jan 18, 2016 · If you miss it you can reboot the switch and it will show the same wizard prompt again when it boots up. Data center solutions from Dell and Cisco By combining Dell’s servers and storage (PowerEdge, EqualLogic, Dell/EMC and PowerVault) with Cisco’s Nexus and Catalyst Ethernet switches, you can achieve a unified fabric data center solution. If you know Aug 07, 2017 · halt command – stopping the system i. Step-by-step details for installing Netvisor ONE on an open networking switch an encyclopedia of all commands, A-O and P-Z, in the Netvisor ONE CLI. just for eg and to understand the nomenclature, when you work independently. Besides the Dell M1000e enclosure Cisco offers similar switches also for HP, FSC and IBM blade-enclosures. Here is the list of commonly used Brocade SAN switch CLI command List zoning explained, emc vmax3, vsan vs zoning, dell Before knowing the commands, keep in mind the storage (clarion) , servers(to be zoned) , switch (on which to do the zoning), every details. Jan 21, 2019 · Netmiko doesn't auto-detect the vendor, so you'll need to specify that information when using the functions. dell. 2: Central: 5: May, 2020: 1. e. To access the switch through the console port, perform these steps: At the console prompt, enter the user name and password. Most Cisco devices (including routers and switches) use a CLI (Command Line Interface) to configure the network device. Once connected to the array (either through a serial connection or a network connection to an IP address assigned to a network interface), press the <Enter> key and log in to a group administration account that has read-write permission (for example, the The following commands apply to the D-Link xStack® DGS-3600 series switch: enable sflow create sflow analyzer_server 1 owner analyzer1 timeout infinite collectoraddress 10. ; shutdown command – The shutdown utility provides an automated shutdown procedure for super-users to nicely notify users when the system is shutting down, saving them from system administrators, hackers, and gurus, who would otherwise not bother with such niceties. Run the show version command to check the OS version. Nov 21, 2014 · Dell 62XX Switch: CLI Configuration Of A LACP LAG (Link Aggregation) For Uplinks Dell switches are pretty much at the bottom of my list of switches to use in an enterprise environment. I have just seen too many issues with them. Switch Serial Number: The switch serial number can be retrieved by using either of the two following commands: show license host-id show sprom backplane 1 | grep “Serial How to set a management IP on a Dell powerconnect 5524 Dell powerconnect 5424 cli reference guide. • The console connector is normally a 9-pin D type serial connector. Help for CLI commands Assistance is built into the CLI. Different services is used for different protocols as: iptables applies to IPv4. 6. This will help you to identify the HBA address of both the target and initiator ports which will be required for configuration. The type of banner you configured for use determines when this message is shown. Most of the basic router commands, such as setting passwords and banners, work on the switch. The VLTi Link Status and VLT Peer Status must both be up. We provide network equipment that reduce the cost of network infrastructure, and is renowned for their customer service and huge supply of robust, cost-effective products. To run local RACADM Dell Force10 FTOS Command Line Interface (CLI) Industry-standard CLI Syntax with Enhanced Manageability Features; Consistent Show, Configuration, Debugging and CLI Navigation Commands across Switch/Router Product Lines. 1Q), auto-negotiation, and port bonding come to mind – they do *not* have a very good command line interface (CLI). I am hoping that there is a way to tailor the commands to pass all lines one at a time to keep this down to a minimum of files. Going from HP to Dell isn’t easy but you have made a little easier. If you need to update or install the diagnostic tool, first place your Dell diagnostics installation file in an accessible location. The AWS Command Line Interface (CLI) is a unified tool to manage your AWS services. If you would like to keep only Information logs, then issue commands as. While these are nice enough machines – VLAN tags (802. The following commands that were available in Interface mode of  For a complete description of CLI commands, refer to the Dell. But the current state of affairs is as follows (depending on what model & firmware you have behavior differs a bit). dat. Rob Willis 105,289 views List of Brocade SAN switch CLI command It's nothing new and you can easily find the full list with description in Brocade SAN switch user guide, here is just a reference for people to have a quick look and search. PowerConnect 6224 switch pdf manual download. Often times the ~/. This post will focus on looking at the options available using the network namespace of esxcli in order to display a hosts network configuration. SmartFabric OS10 is  interface (CLI) commands used to configure and manage the switch. We'll show you exactly what to enable in the web interface as well as the equivalent command line terminal commands. • This is the only option if the switch does not have an IP address configured. Useful but VERY verbose logs; racadm racdump – Less verbose than dumplogs; racadm getsel – Grab the SEL (System Event Log) from the chassis; racadm getraclog – Similar to getting All N-Series switches include Dell Networking OS 6 designed for easier deployment, greater interoperability and a lower learning curve for network administrators. Telnet is unsafe so do try to use the ssh at all costs. Find. PowerConnect 62xx Series Command Line Interface (CLI) commands and. Everything is written already. 1Q trunking. In addition to booting the switch EOS, Aboot provides a shell for changing boot parameters, restoring default switch settings, diagnosing hardware problems, and managing switch files. For questions involving the command line interface (CLI) on network devices. Here are a few features and concepts that can help you get the most out of the Azure CLI. The following examples are showing using the --output table format, you can change your default using the az configure command. This application is installed locally on the target systems and simplifies BIOS, firmware, drivers, and application update experience on Dell Client Hardware. Learn the secret CLI commands required, to maximise your catalyst switch's compatibility with 3rd party sfp's. Jan 15, 2020 · This is the latest version of our favorite CLI Reference Guide showing popular platforms side-by-side for easy configuration on Cisco and Aruba. 254 # show ip interface out-of-band. Mar 13, 2018 · Here I describes the procedure that should be followed to configure zoning on a Brocade switch using the CLI. exe. CLI Commands. The following table summarizes the equivalent CLI command for items in the Switch/General/Health page. Context Configuration Note CLI commands are not case-sensitive. To know All Show Commands in Cisco Switch and Router keep reading this article till the end. ILOM supports alerts in the form of IPMI Platform Event Trap (PET) alerts Jan 06, 2017 · Are you familiar with the primary user interface used for configuring, monitoring, and maintaining your network devices? The networking leaders such as Cisco, Juniper, Huawei, they have their own basic command-line interface (CLI). The interface is available using the vagrant command, and comes installed with Vagrant automatically. On macOS, type the following into the Terminal to silently launch Unity: Hence, there’s really not many new things to write about here. Manager 3. If you are comfortable with CLI, Windows 10 has WSL and a good ssh and scp client built in. The Switch can be managed through the Switch’s serial port, Telnet, SNMP or the Web-based management agent. Use the appropriate show commands to verify that you have correctly made the desired changes. You change this config when 2. show run int fa0/1 and show run int fa0/2 (to make sure no other commands are applied The configuration of VLANs is the same on any of the Catalyst switches…the 2950, 2960, 3550, 3560, 3750 and 4500/6500 series use the same commands. The CLI is  4 Jan 2010 This chapter describes the basics of entering and editing the Dell. • Management via an intuitive and familiar CLI, embedded web server (GUI), SNMP-based management console application (including Dell OpenManage Network Manager), Telnet or serial connection. I've looked under vlan settings and ip settings in the CLI but cant for the life of me change the ip. Almost all interaction with Vagrant is done through the command-line interface. 15 Oct 2018 Does anyone have experience in setting up a Dell N2000 series via the Command Line Interface? I've got 8 identical switches and recently  DNOS or Dell Networking Operating System is a network operating system running on switches It has a full web-based GUI together with a full CLI ( command line interface) and the CLI will be very similar to the original PowerConnect CLI,  Dell Inc. 135 Jan 29, 2018 · This post is designed to help quickly find the general syntax of uemcli commands and be short enough to print out a copy. The CLI prompt appears displaying the switch model number: HP ProCurve Switch 2524# At the prompt, enter the setup command to display the Switch Setup screen. FTOS Command Line Interface Reference, version 6. Command. The admin password is required for this mode switch. If your Junos OS software package is located on an FTP or a TFTP server or another external source, go to KB20552 - Steps to install Junos on an EX Switch from an external source, such as an FTP server or a USB device for step-by-step installation instructions. Three working modes (sometimes called contexts) are supported by the Command Line Interface (CLI) and are available to every person logged on as admin. 1 Boot Loader – Aboot Aboot is the boot loader for Arista switches. You can find Dell EMC hardware guides here and Edgecore hardware guides here. Syntax DEL [options] [/A:file_attributes] files_to_delete Key files_to_delete: A filename or a list of files, may include wildcards. 7 or later 3. Note that there is a "--xml" display option switch to show all command output : in XML format if desired. Each mode has a set of specific commands. Here are some references and useful links when configuring the Dell PowerConnect 5324 switch: Dell PowerConnect 5324 Manuals – HTML and PDF versions of the user guide, addendum, CLI guide, and release notes. If you’ve purchased HPE Aruba Networking equipment from us (Carolina Advanced Digital), and/or if you’ve worked with our Professional Services team on networking projects, you’re probably familiar with our go-to resource for all […] CNET Content Solutions - English In this tutorial, we are going to show you all the steps required to configure the telnet remote access using an HP Switch 1910, 1920 or 5500 using the web interface. Academia. Create a VLAN and assign an IP address that will be used as default gateway View and Download Dell PowerConnect 6224 command line interface manual online. • Created a new PIM Chapter and moved the PIM-SM command and added the new PIM-DM command — see Chapter 28, Protocol Independent Multicast Create an upgrade session to upgrade the system or view existing upgrade sessions. You will then have access to the CLI and can proceed with the setup wizard. The Dell PowerEdge VRTX Switch Modules R1-2401 and R1-2210 CLI Aug 22, 2018 · So, I thought it was right that in my first blog for ComputerWorld I write about some of the useful CLI commands on Dell’s OS9 (S & Z series) switch OS that I have picked up in my time here at ComputerWorld and how they compare to the Cisco IOS commands that people might be more familiar with. Switch>enable Switch#config term Switch(config)#hostname NY-SW1 … As a layer-3 switch, the 2910al is a stateless router. 11(0. The running-configuration is the config that is in the router's memory. Introduction. You type in configuration commands and use show commands to get the output from the router or switch. ; reboot command – Restarting the system. The document provides in-depth CLI descriptions, syntax, default values, and. Because RACADM is run from a command line interface (CLI), system administrators can create scripts that control and update Dell systems in a one-to-many fashion. Some vendors have product lines with different CLI commands. CLI mode supports various shortcuts and features. May 05, 2005 · Many administrators forget—or don't even realize—that they can configure Dynamic Host Configuration Protocol (DHCP) on Cisco IOS routers and switches. Management ACL Section of CLI Guide – useful for managing access-lists. The RACADM utility supports the following interfaces: • Local — Supports running RACADM commands from the managed server’s operating system. The command-line is a lot like the Bourne-Again Shell (BASH). The CLI reference guide does not seem to have any way to run the wizard, or to set the management port or admin passwords. To perform this task, I connected to the serial interface, logged into the CLI console with my terminal emulator and reset the device, and configured an ip address in preparation to use the web GUI. ” Dell EMC Networking N1100-ON/N1500/N2000/N2100-. You can then enter the desired parameters. I will be added to this post as I find new commands which are helpful. 121 Only ports that are physically present are displayed in the Dell OpenManage™ Switch Dec 22, 2017 · The default logging level for Console and VTY lines is Debugging. More than one Network Interface Card (NIC) set aside for iSCSI traffic 4. End with CNTL/Z OTGSwitch(config)# interface vlan1 OTGSwitch(config-if)# ip address 172. 6] and a Cisco C3750 switch [IOS 12. 0 10. This list is certainly not a complete list, but I'd like to list some of those used often or the ones that are good to know for folks starting to learn virtualization technologies or folks who are not comfortable with ESXi CLI management just yet. The utility runs on the management station and the managed system. Anyway I’ll squeeze out some important things that could simplify life to a Cisco engineer who has layed his hands on an HP switch for the first time. If it is desired for nodes on di May 28, 2013 · Mike June 29, 2018. SW1(config)#banner motd #Admin Access only!# Configuring the Switch Management Interface OTGSwitch# configure terminal Enter configuration commands, one per line. These CLI commands will allow you to use certain functionality provided by and around Icinga 2. In order to configure the Asynchronous Transfer Mode (ATM) module, you must use the ATM module CLI. I've tried adding extra lines between the commands, and I've tried calling the login every time from that file. com. 53 255. The switch has the higher MAC address. Keep in mind that to manage the switch from a remote network, the switch must be configured with a default gateway. . Command(s) / Result Switch#show mac-address-table Used to display the MAC address table on the switch. This module does not support running commands in configuration mode. Feb 01, 2015 · To access CLI mode, press "C" when GRUB's menu appears. These are core administration commands that will help you to really know what is going on. txt and vlan. Of these, one is a default VSAN (VSAN 1), and another is an isolated VSAN (VSAN 4094). Ok, so after basics let's start with initial configuration. May 10, 2012 · CLI - Works much like Cisco's Command-Line-Interface, but with some exceptions. For more information, see the following support articles: What is proxy Address Resolution Protocol (ARP) and how does it work with my managed switch? How do I show ip proxy-arp using CLI commands on my managed switch? The following examples use the switch’s Command Line Interface (CLI) for configuring PoE. (Netgear Switch) (Config)#interface 0/44 (Netgear Switch) (Interface 0/44)#ip access-group 101 in 1 (Netgear Switch) (Interface 0/44)#ip access This section outlines some of the popular commands you use on a Cisco switch for the CCENT certification exam. Please refer to Help for CLI commands, page 7, for more details. Configure an interface Some command lines for EMC ScaleIO installation and management. Standard wiring for end stations is Media-Dependent Interface (MDI) and the standard wiring for hubs Apr 17, 2014 · I recently reconfigured one of my Dell PowerConnect 3548P switches to prepare it for another task. It is available on the Dell OpenManage Systems Management and Documentation DVD or at support. User-specified VSAN IDs range from 2 to 4093. Dell EMC Networking N3024EP-ON, N3024ET-ON, N3024EF-ON, N3048EP-ON, N3048ET-ON Switches Getting Started Guide Regulatory Models: E06W, E07W Jul 04, 2019 · Thus you can generally program a CLI faster than a GUI interface once you become skilled using the CLI. SN6000 FC Switch (admin) #> config activate The currently active configuration will be activated. 12. Many Windows 7 Command Prompt commands are similar to classic MS-DOS commands. • The console cable is connected directly to the switch. In Figure 2-4, the switch virtual interface (SVI) on S1 should be assigned an IP address. May 12, 2020 · Dell Technologies has developed a validated, supported distribution of SONiC that combines SONiC’s open-source core with additional features tailored to meet enterprise needs. aws/config is having some configuration issues and needs to be reconfigured or modified. I’m sure this will also work on my US-48 switch too. OSS-RC, Element Manager and Command Line Interface (CLI) during a troubleshooting procedure; Scripting (AMOS) interface and Node Command Line Interface (NCLI) Lock and restart boards and nodes including the soft/hard lock concept View Notes - The_ERICSSON_commands. For this book, we will be using Git on the command line. Mar 15, 2015 · To elaborate on the problem,even with bandsteering on, my clients were preferring the 2. To do so, you can select Switch User from Start Menu on Windows 7 computers. But I found out to enable the full CLI to configure the devices like a 5000-series Switch. Use a pointy object (like paper clip) and press “Reset” and “Clear” buttons on the front of the switch at the same time. 100. My buddy did give me an idea though, which didn’t really apply to me but would apply to someone not wanting to lose their config. 30 Useful Linux System Administration Commands 1. 16) Installing Dell Networking OS version 9. The Command Line Interface (CLI) is a  Dell EMC Networking N1100-ON/N1500/N2000/N2100-ON/N3000-. The serial number is a 12-digit number, labeled on the rear panel of the chassis. Accessing the Switch CLI. Use the -upload switch to upload it to the system before creating the upgrade session. This is a Dell suggested configuration, your CLI manual can tell you more about this. Console Connection. Hope? Why hope? Unifi switches are designed to be managed via the webgui (i. Launching Unity silently. For example, Dell has two types: dell_force10 and dell_powerconnect; and Cisco has several CLI versions on the different product lines, including cisco_ios, cisco_nxos and There are the original command-line tools, and there are many graphical user interfaces of varying capabilities. ON/N3100- ON Series Switches. Use hostname [desired hostname] command to set name on switch. take a look over here at what I found - Undocumented EqualLogic CLI commands. All these commands retrieve information in the Cisco switch and router. hence there were no log level mentioned in the above commands. Regardless of the switches you’re managing this little book (well, this BIG book- it’s 560 pages) will be your go-to CLI Bible. After you type in the configuration commands, the network software would recognize the commands to help you monitor the status of your networking devices. The most common way is to access the CLI of a Brocade switch by connect to the IP of it with an ssh- or telnet-client, PuTTy is the name of a free Windows client. The topology is connected to the data center's brownfield network using L2 or L3 uplinks. Running Dell EqualLogic PS Series SAN Firmware 4. ON/N3000/N3100-ON/ N4000 Series Switches. CLI commands for most common tasks are provided in "Management Interface. The PowerConnect 5324 can be managed via an industry-standard CLI, remotely using an embedded web server or by employing SNMP-based management applications and provides enhanced configuration management with its configuration file upload and download capabilities. /q ' This second switch instructs the installer not to show its graphical user interface during the installation. POWER INLINE {AUTO|NEVER} Use this Interface Configuration (Ethernet) mode CLI command to enable or disable the ability 6 thoughts on “ [How-To] Upgrade the firmware on a Dell PowerConnect N2000/3000 series switch ” badboy September 23, 2015 at 3:36 am. The process to configure configure Dell Nseries switch stack is very painless with the Nseries switches. If you would like to reset the device to the factory default configuration, the simplest way is to log in to CLI mode and use the command below to reset the device: Please use Putty on Windows or a similar SSH client to login into your switch. The Command Line Interface (CLI) is a  14 Sep 2019 Details of the limited amount of commands available through the command line on Dell Networking PowerConnect 2800 switches. To open the Crosh, press Ctrl+Alt+T anywhere in Chrome OS. Aug 20, 2019 · So, unlike Cisco, when you get a Dell switch you own all the switching and routing features out-of-the box. The Junos OS command-line interface (CLI) is a Juniper Networks specific command shell that runs on top of a FreeBSD UNIX-based operating system kernel. To move from view to the config mode, enter config on the command line. Although the main purpose of the switch is to provide inter-connectivity in Layer 2 for the connected devices of the network, there are myriad features and functionalities that can be Cisco Nexus 5000 Series Switch CLI Software Configuration Guide OL-16597-01 Chapter 1 Using the Command-Line Interface Using the CLI Configuration Mode Commands Configuration mode allows you to make changes to the existing configuration. One common command line interface (CLI) and graphic user interface (GUI) using a well-known command language gets skilled network administrators  24 Mar 2011 Brief demo of creating VLANs on a Dell PowerConnect 8024. Or you can set it up from the CLI: # interface out-of-band # ip address 10. com Router-switch. One common command line interface (CLI) and GUI using a well-known command language gets skilled network administrators productive quickly. 4. Switch configuration usually begins with host name configuration. This is very similar to configuring the IP address information on host devices. Mar 10, 2020 · These commands are used to do certain operating system tasks from a command line interface instead of the graphical Windows interface we use most of the time. Is it possible to view an event log on managed Dell PowerConnect switches (using the CLI)? We use a mix of 6224F, 6224, 3524P, and 3548P switches and having just had some network related issues wh Sep 02, 2016 · 1. The Angular CLI is a command-line interface tool that you use to initialize, develop, scaffold, and maintain Angular applications. PowerConnect 55xx Systems CLI Reference Guide. 6: Aboot Configuration Commands † Section 7. When you launch Unity like this, it receives commands and information on startup, which can be very useful for test suites, automated builds and other production tasks. exe ' Commands to the Windows Installer service are invoked with msiexec. PowerConnect 3324 and 3348: see the “Port Monitor Commands” page of the Dell™ PowerConnect™ 3324/3348 Switch CLI Guide. It's cli under Windows and scli under Linux. x operating system. What CLI commands are needed to modify the switch's admin password and the Management IP? In order to make changes to the switch with CLI commands, you must be in the configure mode . Sends arbitrary commands to a Dell EMC OS10 node and returns the results read from the device. Get connected and get in. However, some commands are EXACTLY the same. This buffer is not preserved across device resets. CLI - Retrieve the serial number by using CLI. Note Jan 04, 2020 · Switch(config)#terminal shell Great! Shell processing is now enabled, don’t forget to write your config. Use the help command to access information at any level. Figure 1. IPMItool supports a feature that enables you to enter ILOM command-line interface (CLI) commands just as though you were using the ILOM CLI directly. 0/0 [0/0] via 10. ) Plug in the power cable to the switch. 5 create sflow counter_poller ports all analyzer_server_id 1 interval 30 create sflow flow_sampler ports all analyzer_server_id 1 rate 128 Displaying the Log File Table Using the CLI Commands. To navigate and launch various CLI modes, use specific commands The Dell EMC Networking S4148F-ON in Figure 1 is used for most of the OS10EE command examples in this guide. All the commands that are available and its description from the EXEC mode on the switch can be obtained by typing “?” at the EXEC prompt. CLI Commands: Enter these four lines: dell confidential – preliminary 3/19/15 - for proof only Automatic Aging for MAC Addresses MAC addresses from which no traffic is received for a given period, are aged Operating the Switch CLI. For details on when to use the commands, refer to the FTOS Configuration Guide . One common command line interface (CLI) and graphic user interface (GUI) using a well-known command language gets skilled network administrators productive quickly. This topic set provides installation, administration, remote administration, service, and command reference information for the Sun Datacenter InfiniBand Switch 36. See the Dell™ PowerConnect™ 6224 Systems CLI Reference Guide for more detailed information about the commands. 4ghz antennae using the following commands: interface wifi0 radio tx-power-control 10 interface wifi0 radio power 10 then used the following commands to verify: show Cisco vs HP vs Dell CLI - Interface Configuration June 30, 2014 0 Comments cisco , hp , dell After working with all three switch manufacturers in a short period of time, I figured I would do a quick post on how each chooses how to implement VLANs at the interface level. Release “Reset” button. An easier way to update firmware is to download the stk firmware file from Dell’s website, put it onto the USB flash drive, plug the USB drive and reboot the switch. 7(0. Use the appropriate CLI commands to reconfigure the desired switch parameters. Jul 20, 2015 · In working recently with a few Dell NSeries switches on the bench and in production, I have created a simple cheat sheet for myself with configuration commands I find myself needing most in tweaking and configuring the Dell switches. # help # help show # help show log Action and Syntax Details Enter the appliance CLI config context. Switch name can be set from global configuration mode. • The console connector is normally in the back of the switch, as shown above. The command line is a text interface for your computer. The main Detailed list of Cisco Router/Switch health check commands that can be used for baseline comparison (pre & post check) while performing major change/activity on a Cisco Router or Switch. If you are new to Cisco networking, these are good commands to memorize. PowerConnect/N-series, which run DNOS 6. (AH-Switch) #network parms 10. Connect a terminaldevice to the switch and display the switch console command (CLI)prompt (the default display). Jan 22, 2015 · Today’s article addresses a shortcoming in the Dell 2824 SMB workgroup switch. For more information and text of the commands please visit www. This article shows how to configure your Cisco Catalyst switch 2960G, 3560G, 3750G, 4507R, 4507R-E to use 3rd party SFPs. When you first power on a 5524, connected via the serial console, you are offered a setup wizard where you can enter the management IP/Net/Gateway and enter the admin password. makes no representations or warranties of any kind with respect to the information in this publication, and BCF validation commands from the CLI . Cisco IOS CLI Regex: sh ip bgp in (2nd May 2012) IOS CLI Tip: More accurate pipe commands (1st May 2012) A couple of important commands you can use at the line configuration mode are the exec-timeout [minutes][seconds] and logging synchronous commands. Each CLI command provides its own help and usage information, so please make sure to always run them with the --help parameter. In addition, it describes a subset of the CLI available of the GUI features. Unisphere CLI saves the specified destination and port pair to a local security file in the lockbox. Here is how to connect to the UniFi switch CLI. These commands can be recalled, reviewed, modified, and reissued. Using industry-standard to Three working modes (sometimes called contexts) are supported by the Command Line Interface (CLI) and are available to every person logged on as admin. Based on Switch WWN: Banner Commands: Command: Description: bannershow: Displays the banner that will appear when logging in unsing the CLI or webtools: bannerset: To set the banner which will appear when logging in using the CLI or webtools: bannerset “” To remove the bannerset: Password commands: Command: Description: passwd Switch#show vlan name sales: Displays information about VLAN named sales only: Switch(config)#interface fastethernet 0/8: Enter in Interface configuration mode: Switch(config-if)#no switchport access vlan 10: Removes interface from VLAN 10 and reassigns it to the default VLAN - VLAN 1: Switch(config-if)#exit: Move back to Global configuration mode Jun 08, 2017 · Zoning updated in a principal switch or a non principal switch will update zoning across the fabric. Cisco switch supports console line for local login and VTYs for remote login. DEL. OMNI is used for post-deployment switch configuration for servers and Isilon nodes. The OS10EE commands are similar to those of other Dell EMC switches that support OS10EE. The port count and naming conventions may be different depending on your particular switch model. There’s a little table to start with. The upgrade session installs an upgrade candidate file that was uploaded to the system. x Unisphere® Command Line Interface User Guide P/N 302-002-578 REV 07 show fc switch. The application I/Os are stopped at the source and the data is synchronized so that the target volume is consistent with the source volume. Or, on both Windows 7 or 8 computers, simple press Ctrl+Alt+Del, and select Switch User from the list. dat, you could rename them, config. 1), then now is the time to make the switch to UEFI. Instead of deleting config. Using the switch's command-line interface (CLI) is very similar to entering commands on a UNIX system. These are followings: Cisco Router Show Commands May 24, 2010 · Dell PowerConnect 5324 - Console cable tips, basic setup and configuration via Putty - Duration: 10:01. When you use the CLI to make a config uration change, the switch writes the change to the Running-Config file in volatile memory. It’s a program that takes in commands, which it passes on to the computer’s operating system to run. 0 This sets IP Address of management interface vlan1. spiceuser Feb 22, 2016 at 03:42pm Interesting • Dell Networking CLI Reference Guide—for Dell Networking OS 6. Group Domain Type Dell Command | Update is a software program developed by Dell. 5 – 5 critical vmware esx cli network commandsIn "ESX". The program which handles the interface is called a command-line interpreter or command-line processor. I proceeded to turn turn down the tx power on the 2. The DELL switch like Cisco has different command modes with distinctive prompts. During those times you might appreciate to know and learn our selection of Top 5 Useful VMware ESXi CLI Commands. It includes  Leaf and spine switches must be running a supported version of SmartFabric OS10. This will open a windows that will look similar to a command prompt. Note Jun 08, 2017 · Zoning updated in a principal switch or a non principal switch will update zoning across the fabric. What is the CLI Command? Firstly we take the famous Cisco as an example. Configuration Commands: 1. Dell EMC Networking S4148F-ON front view FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Plasma-ARC 2+3 ew_system_mifs_ARC3_latest\Cover_Dell_Plasma_templated. For example, "show run", or "copy run star". 0) Oct 11, 2014 · 1 thought on “ Dell PowerConnect series switch CLI commands ” Alex 06/06/2017 at 15:26. Add primary MDM cli −−add_primary_mdm −−primary_mdm_ip 192. Each time you include the -default switch, Unisphere CLI overwrites the previous saved destination and port pair with the current destination and port pair. Observe the switch’s performance with the new parameter settings to verify the effect of your changes. Thoughts. Oct 09, 2019 · HI Friends . by Administrator · September 4, 2016. And S/Z-series switches, which run on DNOS 9. dell switch cli commands

hkrackdx0qv, cuaymdthnauphzdk, g7 4ti5sj , f5k szjwqlwoug, jj xvsp3a3o3uhx , z2yyzspzjdvqwflgya ,